   Mobile:86-13611976994
  E-mail:Grace@acrel.cn
Home » Products » Energy Meter » AC Energy Meter » 1 phase energy meter din rail ADL100
Share to:

1 phase energy meter din rail ADL100

● AC220V
● 10(60)A,20(100)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 1
● DIN 35 mm
 
CE EAC RoHS
Quantity:

1 phase energy meter din rail ADL100

12345678Direct access9Transformer access10




Dimension drawings of 1 phase energy meter din rail ADL100

Instrument dimensions

Note:The torque should not be greater than 4.0N·m

External transformer dimensions




Typical connection of 1 phase energy meter din rail ADL100

din rail energy meter



ADL100 single phase electric meter is designed for single phase active energy measurement on low voltage system, in the same time it can measure the electrical parameters like voltage, current, power and so on. There is also RS485 can be chosen. This power meter has advantages of smaller volume, high precision, good EMC, easily installing etc, All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.



Function description of 1 phase energy meter din rail ADL100


Function

Function description

Function provide

■ standard/□ optional

Measurement of kWh

Single-phase active kWh (positive and negative)

Measurement of electrical parameters

Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency

LCD Display

8 bits section LCD display

Key programming

3 keys to set parameters like code, address, baud rate, multi-tariff and communication protocol 

Pulse output

Active energy pulse output

Multi-tariff

Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

□F

Communication

Communication interface: RS485, Communication protocol: MODBUS-RTU

□C

Infrared communication


Technical parameter of 1 phase energy meter din rail ADL100

11

Electric performance

Input voltage

Reference voltage

AC 220V

Reference frequency

50Hz

Power consumption

<10VA

Input current

Basic current

10A

Maximum current

60A

Starting current

4‰Ib

Consumption

<4VA (Maximum current)

Measurement performance

Accuracy of measuring

1class

Range of measuring

000000.00~99999999kWh  

 Clock accuracy

Error≤0.5s/d

Active pulse

 Pulse width

80±20ms

 Pulse constant

1600imp/kWhLED

Communication

Interface

RS485(A+B-)

Connection mode

Shielded twisted pair conductors

 

Protocol

MODBUS-RTU


Mechanical performance

Outline (Length × Width × Height)

88mm×36mm×70mm 


Work environment

Temperature range

 Work temperature

-25℃~55℃

 Storage Temperature

-40℃~70℃

 Relative humidity

≤95%(No condensation)

 Altitude

<2000m