●AC220V
●10(80)A
●RS485(MODBUS-RTU)
●Set parameters
●LCD display
●kWh Class 1
●DIN 35 mm
 
CE EAC RoHS MID
Quantity:

Energy  meter din rail 1 phase ADL200

WeChat26315994deb4ace529437a9f18e93b58

WeChat9f342dc492934f8af0604f3ea6043f5fWeChat3bd2e1a8ab0eea5483ec35788f5ebeafWeChatd0b8b149b8e501c7011f6d4ba1e73074WeChatf044c1803c1539172fa729b44a4e28e1WeChat6f3d2f06415e607f67cbe4983e55e108WeChatbe022f4cd2bff24e883f403850779f3d

Dimension drawings of Energy  meter din rail 1 phase ADL200

Meter outlook and size




Typical connection of Energy  meter din rail 1 phase ADL200

din rail energy meter



ADL200 single phase electric meter is designed for single phase active energy measurement on low voltage system, in the same time it can measure the electrical parameters like voltage, current, power and so on. There is also RS485 can be chosen. This electricity meter has advantages of smaller volume, high precision, good EMC, easily installing etc, All meters meet the related technical requirements of electricity meter in the IEC62053-21、IEC62053-22 standards.




Function description of Energy  meter din rail 1 phase ADL200


Function

 

Function description

Function provide

■ standard/□ optional

Measurement of kWh

Single-phase active kWh (positive and negative)3 months historical energy data frozen storage

 

Measurement of electrical parameters

Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency

LCD Display

8 bits section LCD display

Key programming

3 keys to set parameters like code, address, baud rate, multi-tariff and communication protocol 

Pulse output

Active energy pulse output

Multi-tariff

Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

□F

Communication

Communication interface: RS485, Communication protocol: MODBUS-RTU

■C





Technical parameter of Energy  meter din rail 1 phase ADL200

Electric performance

Input voltage

Reference voltage

AC 220V

Reference frequency

50Hz

Power consumption

<10VA

Input current

Basic current

10A

Maximum current

80A

Starting current

4‰Ib

Consumption

<4VA

Measurement performance

Accuracy of measuring

1 class

Range of measuring

000000.00~99999999kWh  

 Clock accuracy

Error≤0.5s/d 

Active pulse

Pulse width

80±20ms

Pulse constant

1000imp/kWh

Communication

Interface

RS485(A+B-)

Connection mode

Shielded twisted pair conductors

Protocol

MODBUS-RTU


Mechanical performance

Outline

Length × Width × Height

90mm×36mm×65mm

Strong current terminal

Torque

<1.8Nm


Work environment

Temperature range

Work temperature

-25℃~55℃

Storage Temperature

-40℃~70℃

Relative humidity

≤95%(No condensation)

 Altitude

<2000m