   Mobile:86-13611976994
  E-mail:Grace@acrel.cn
Home » Products » Current Transformer » Hall Sensor » Open core hall sensor
Share to:

Open core hall sensor

● Excellent accuracy
● Low temperature drift 
● Wide frequency bandwidth 
● Optimized response time
Quantity:

Open core hall sensor

index

Appearance

2

Technical Data

3

index2index3





Dimension drawings of Open core hall sensor

 

                                                     Fig.1                                                                                                          Fig.2

Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.




Typical connection of Open core hall sensor


Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.


Technical parameter of Open core hall sensor

1446074178112364544_MTYxMTc0OTE2NjEzNTIwMTYxNWsuanBn

Technical parameters

Data

Split/closed  open-loop

Hall (true RMS)

Output

Nominal value

Voltage: ±5V/±4V

Current: 4-20mA

Zero offset voltage (current)

Voltage: ±20mV

Current:±0.05mA

Offset voltage (current) drift

Voltage: ≤±1.0mV/℃

Current:±0.04mA/℃

Linearity

≤0.2%FS

Power voltage

DC±15V

DC 24V

Bandwidth

 0-20kHz


Response time

   ≤5us

≤1ms

Dielectric strength

Permissible 2500VAC between input/ output and power supply at the power frequency

Accuracy class

1.0

Ambient conditions

Temperature

Operating temperature:-25℃-+70℃;

storage temperature: -40℃-+85℃

Humidity

≤95%RH, no dew, no aggressive gas

Altitude

≤3500m