● True RMS Measurements
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp
● Alarms and SOE Logs
● External Option module
 
CE
Quantity:

Panel three phase energy meter APM series

1234567



Dimension drawings of Panel three phase energy meter APM series

Meter and panel opening size(unit: mm(in))

Multiple meter installation (unit: mm(in))




Typical connection of Panel three phase energy meter APM series


APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology.

APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.

This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording (SOE) module with T-Flash (TF) card, network communication module, can achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize high-speed data transmission and networking function.




Function description of Panel three phase energy meter APM series

Function

APM800

(class 0.5s)

APM801

(class 0.2s)

APM810

(class 0.5s)

Measured parameters

Total electrical measurement

Four-quadrant energy

Pulse output of energy

Pulse output of active/reactive energy

Demand

Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)

Extreme value statistics

Extremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total harmonic of current, total harmonic of voltage in this month and last month (including time stamp)

Power quality

Unbalance of current, line voltage, phase voltage

Voltage phase angle, current phase angle




Total (odd, even) harmonic content of voltage and current

×

×

Harmonic content of voltage and current (2-63 times)

×

×

Voltage crest factor

×

×

Telephone waveform factor

×

×

Current K-factor

×

×

Alarm records

A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card 

Event log

Record the most recent 128 event records, support extended records by TF card

Communication

Modbus protocol

I/O

2 digital inputs + 2 digital outputs (2DI+2DO)

Extensions

MD82

8 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)

MLOG

TF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)

MA84

8 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)


MCM

1 RS485/Modbus-RTU, support master mode or slave mode


MCP

1 Profibus-DP


MCE

1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol

Note ①: Accuracy of  2~42 times harmonic measurement in the frequency range of 45~65Hz is 1%, accuracy of 43~63 times harmonic measurement in frequency 50Hz is 2%.



Technical parameter of Panel three phase energy meter APM series

WeChat912201c3f73eed27c65cfe4b7797d611

Technical Parameters

Index

Signal

Electrical network

Three-phase three-wire, three-phase four-wire, see the wiring diagram;

Frequency

4565Hz

Voltage

Rated valueAC 100V110V400V690V

Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;

Power consumption: < 0.5VA (per channel);

Current

Rated value: AC 1A, 5A, support 4 mm2 line access;

Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;

Power consumption: < 0.5VA (per channel);

Measurement accuracy

Voltagecurrent and power

class 0.5s/class 0.2s (APM800APM810/APM801)

Active power

class 0.5s/class 0.2s (APM800APM810/APM801)

Reactive power

class 2

Harmonic

1%2rd~42nd)、2%43rd~63rd

Switch inputs

Dry contact inputs, built-in power supply;

Relay outputs

Contact type: open contact in main part, changeover contact in module;

Contact capacityAC 250V/3A  DC 30V/3A

Pulse output of energy

Output mode: Optocoupler pulse with open collector;

Pulse constant40005A)、80001Aimp/kWh

Analog outputs

DC 0mA20mA4mA20mA0V5V1V5V output, accuracy class 0.5%, load resistance ≤ 500Ω;

Analog inputs

DC 0mA20mA4mA20mA0V5V1V5V iutput, accuracy class 0.5%

Storage card

Standard Capacity:4G,TF Card Up to 32G Capacity;

Communication

RS485 interface/Modbus-RTU protocol and DLT645 protocol

Profibus-DP interface/Profibus-DP protocol;

RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;

Power supply

Working range: AC/DC 85V265V or AC/DC 115415V(P2);

Power consumption: Power consumption of the main part ≤ 15VA;

Safety

Power frequency withstand voltage

The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;

The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;

The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;

The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;

The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;

The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;

Insulation resistance

Inputsoutputs to the shell>100MΩ

Electromagnetic compatibility

Meet IEC 61000 standard (Level 4);

Protection level

Display panel IP52

Environment

Operating temperature: -20 °C ~ +65 °C;

Storage temperature: -20°C+70°C;

Relative humidity: ≤95% without condensation;

Altitude: ≤2500m;

Standards

IEC 60068-2-1

IEC 60068-2-2

IEC 60068-2-30

Environmental Testing-Part 2-1:Tests Test A:Cold IDA

Part 2-1:Tests Test B:Dry heat

Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)

IEC 61000-4

Electromagnetic compatibility-Testing and measurement techniques

IEC 61557-12

Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12

Performances measuring and monitoring devices(PMD)

 IEC 62053-22

Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energyclass 0.2s and 0.5s