AMB Smart Alternating-current Bus Bar Monitor is a new development to cater for smart power bus bar.
Quantity:

Smart AC electric energy meter

AMB Smart Alternating-current Bus Bar Monitor is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm

function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time.

By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring, ensuring safe and reliable operation of the system. The smart bus bar monitor has several benefits such as flexible and convenient wiring so that it is a good substitution of the traditional centralized array cabinet.




Dimension drawings of Smart AC electric energy meter

  

RS485/Modbus-RTU Communication                                    LORA Communication




Typical connection of Smart AC electric energy meter


Technical parameter of Smart AC electric energy meter

AMB100-A/AMB110-A

Measured parameters

Voltage, current, frequency, active power, inactive power, power factor, active energy, inactive energy, 2nd-63rd harmonic, temperature, leakage

Voltage

Rated value

3x220/380VAC

Range

±20%

Overloading

1.2 times than the rated voltage value continuously or 2 times than the rated voltage value instantaneously per second

Current

CT

AMB100-A : 5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA

AMB110-A:100A/20mA

Range

1%-120%

Overloading

1.2 times than the rated current value continuously or 10 times than the rated current value instantaneously per

second

Input frequency

45-65Hz

Measurement accuracy

Voltage/current : grade 0.2; active power/energy: grade 0.5; inactive power/energy:grade 1; temperature:±1℃

Auxiliary power supply

AMB100/110-A(/W)  triggered upon receipt of request

signal

AMB100/110-A(/W)-P1follow the bus bar voltage

functions

Temperature

detection

-20-150℃

Leakage

0-1A

Digital input

2 dry-contact inputs

Digital output

2relayoutputs;contactcapacity  3A/30VDC,

3A/250VAC

Communication

Via RS485/Modbus-RTU or LORA antenna

Installation

Use DIN35mm rail

Protection

IP20

Pollution level

2

Environment

Temperature/ humidity/ altitude

Working temperature:-20-60℃ Storage temperature:-25-70℃ Relative humidity:≤93%

Altitude:≤2500m

Safety

Insulation

The minimum insulation resistance between all terminals

and conductive components of the shell is 100MΩ.


Withstanding voltage

When a voltage of 2kV AC is applied between the voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage shall be less

than 2mA and no breakdown or flashover shall occur in 1min..

Electromagnetic immunity

Electrostatic discharge

immunity

Class 4

Radio frequency electromagnetic

immunity

Class 3

Transientburst

immunity

Class 4

Surge immunity

Class 4

AMB120

Measurement accuracy

Temperature:±1℃

Auxiliary power supply

220VAC, discrete

functions

Temperature

detection

-20-150℃

Communication

Via RS485/Modbus-RTU or LORA antenna

Installation

Use DIN35mm rail

Protection

IP20

Pollution level

2

Environment

Temperature/ humidity/ altitude

Working temperature:-20-60℃ Storage temperature:-25-70℃ Relative humidity:≤93%

Altitude:≤2500m

Safety

Insulation

The minimum insulation resistance between all terminals

and conductive components of the shell is 100MΩ.

Withstanding voltage

When a voltage of 2kV AC is applied between the auxiliary power supply and temperature sensors, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min..

Electromagnetic

Electrostatic

Class 4

immunity

discharge

immunity


Radio frequency electromagnetic

immunity

Class 3

Transientburst

immunity

Class 4

Surge immunity

Class 4