Multi-Loop Energy Meter, ADW210 Series
Multi-Loop Energy Meter, ADW210 Series
The ADW2xx series rail-mounted multi-loop power meters are designed to measure the full electrical parameters of multiple three-phase circuits and can be connected to the current inputs of up to four three-phase circuits simultaneously. Voltage and current, power, power factor, phase angle, unbalance, harmonics and other parameters can be measured directly or indirectly.
| Power measurement:Voltage、current、power factor、frequency、active power、reactive power、apparent power |
| Harmonic function:Total harmonic、sub harmonic (2~31) |
| DI/DO:Main module 2DI2DO; CT connect 2DI4DO (direct connect) |
| Communication:Infrared; RS485 MODBUS-RTU and DL/T645 |
| History energy:12 month energy record |
3-phase 4-wire Wiring of ADW210 monitoring 4 3-phase Circuits
Wiring between ADW210 Main Body and MTL&MK Extra Function Module through RJ45 Interface
Wiring between 1 ADW210 Main Body and 1 AWT100 Communication Module
| Auxiliary power | AC/DC 85~265V;consumption≤ 10VA; | |
|
input |
Frequency | 45~65Hz; |
| Voltage | AC 3×220V/380V; | |
| Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; | ||
| Power consumption:≤ 0.5VA; | ||
| Current | AC 5A 、100A 、400A 、600A;(External opening transformer) | |
| Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s; | ||
| Power consumption:≤ 0.5VA; | ||
| measurement accuracy | Frequency 0.05Hz, voltage and current 0.5 level, active electric energy level 1, reactive electric energy level 2; | |
| 2-31 times harmonic accuracy: ± 1%; | |||
| Features | Pulse output | Output mode: optocoupler pulse with open collector; | |
| Communication | RS485 、Modbus-RTU;Baud rate 1200~38400; | ||
| Switching | input | Dry contact input 、Built in power supply; | |
| output | Output mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A; | ||
| Switching Module | Power | RJ45 interface 、DC 12V 、Power consumption≤ 1W; |
| Communication | RJ45 interface 、Modbus-RTU;(Communication with the main Part) | |
| Switching input | Dry contact input 、Built in power supply; | |
| Switching output | Output mode:Relay normally open contact output;contact rating:AC 250V/3A DC 30V/3A; | |
| Temperature and leakage module | Power | RJ45 interface 、DC 12V 、Power consumption≤ 1W |
| Communication | RJ45 interface 、Modbus-RTU;(Communication with the main Part) | |
| temperaturemeasurement | -20~100C; | |
| Leakage measurement | 10~3000mA; | |
| measurement accuracy | temperature ±2C、Leakage1.0%; |
| Safety | Power frequency withstand voltage | >AC 2kV/ 1min; |
| Insulation resistance | > 100MΩ; | |
| Environment | working temperature:-20C~+60C;Storage temperature:-40C~+70C;relative humidity:≤95% No condensation;Altitude:≤2500m; | |
| electromagnetic compatibility | Better than grade 3; | |